Set poll interval

Command

AT+POL=<sensor-address> <metric> <poll-interval>

Response

OK | ERROR <code>

Description

Set the poll interval for the sensor with ID <sensor-address>. The <sensor-address> field and the <metric-id> are each a 2-digit hex string. The <poll-interval> formatted as a decimal string. When the poll interval is changed successfully, the motherboard responds with OK. Otherwise, e.g., when an invalid sensor ID is specified, the response is ERROR followed by an error code.

Bedenkingen geof (maar moet dat hier)? • Minimum poll interval: 5 minutes? (Not enforced yet in software). • Maximum value 65535 (approx.. 18 hours). • A poll interval of 0 will be treated as “never poll”, sensor will operate threshold-based.

Example

Command>  AT+POL=01 01 600
Response> OK

Set poll interval for sensor 0x01, metric 0x01 to 600 seconds, i.e., every 10 minutes.